Laboratory Analysis Services

ANALYSIS VITA is staffed by Chemicals and Chemical Engineers with long-term experience and expertise in the field of measurement, control and management of water and waste. Based on our experience and the use of state-of-the-art machinery and methods from well-educated scientific staff, we aim to serve the customers with respect, reliability and confidentiality in the field of physico-chemical and microbiological analyzes of water and waste.

The basic idea that was applied since the foundation of the company, was the use of specialized laboratory equipment of cutting-edge technology, suitable simulation equipment and on-site testing and staffing with scientific and technical staff with specialized knowledge and long-term experience in water management, waste water management and automation processes of them.

See the laboratory facilities of ANALYSIS VITA.

In our laboratory we conduct microbiological and physico-chemical analyzes of water for control of its suitability for irrigation and water supply for human use, as well as microbiological and physico-chemical analyzes of waste water.

For the chemical analysis of water, that we measure the water salts, no particular pretreatment is required (conductivity, pH, total dissolved solids, chlorides, sulphates, calcium, magnesium, carbonates, bicarbonates, nitrate, nitrιtes, boron, etc.). Just collect the water to be examined in any clean bottle and transfer it to the lab.

Basic Drinking Water Chemical Analysis

Column 1 Column 2
pH Conductivity
Total Dissolved Solids (T.D.S.) Hardness
Carbonates (CO3) Όξινα Ανθρακικά (HCO3)
Alkalinity P Alkalinity M
Chlorides (Cl-) Nitrate (ΝΟ3)
Nitrites (ΝΟ2) Ammoniacal (ΝΗ4+)
Phosphates (Ρ2Ο5) Fluorones (F-)
Sulfates (SO4-2) Silicates (SiO2)
Calcium (Ca) Magnesium (Mg)
Potassium (Κ) Sodium (Na)
Copper (Cu) Zinc (Zn)
Manganese (Mn) Iron (Fe)
Chlorine (Cl2)

For the microbiological examination of the water, where the presence or absence of pathogenic microorganisms (total number of microbes, coliforms, pseudomonas, enterococci, etc.) is checked, it is necessary to collect the test sample in a special sterilized bottle provided by our laboratory.

Basic Drinking Water Microbiological Analysis

Column 1 Column 2
Total Microbiological Flora/Count (TC) at 22°C and 36°C Enterococci
Coliforms Pseudomonas Aeruginosa
Clostridium Perfringens

For restaurants, cafes, food preparation and handling laboratories as well as for public swimming pools, our laboratory undertakes on-site water sampling, sample transfer to the laboratory, and the outcome of whether the water sample is free or not of pathogenic microorganisms and suitable for drinking.

Pool Water Analysis

Column 1 Column 2
pH Color
Free Chlorine (Cl2) Ammoniacal (ΝΗ4+)
Total Microbiological Flora/Count (TC) at 22°C and 36°C Coliforms
Enterococci Pseudomonas Aeruginosa

Prevention & Rehabilitation Services for Legionella Pneumophila (Legionnaires’ Disease)

ANALYSIS VITA
ANALYSIS VITA is also active in the processes of controlling the development, environmental conditions, risk and prevention of bacterial growth in water-containing systems.

Methods for identifying and controlling problems associated with Legionnaires’ disease in hotels, hospitals or residential complexes are in line with the EWGLI and WHO 2007 (World Health Organization) specifications. ANALYSIS VITA undertakes sampling on sterile 1 liter samplers. The samples are analyzed in the proprietary analytical laboratories directly.

  • Warm Water Network
  • Cold Water Network
  • Hydrotherapy Systems
  • Heated Pools
  • Humidifiers
  • Fountains & Water Elements
  • Cooling Towers

Technical guidelines for the prevention and control of Legionella, using operating temperature control or chemical additives, are provided by our specialized Chemical Engineers to maintain the physicochemical and thermal fields that will prevent the development and settlement of the networks.